| Signal |
Pin Number |
Description |
| Output 1+ |
1 |
Optocoupler collector for output 1. For sourcing
applications connect "+" to voltage. For sinking
applications connect "+" to load.
|
| Output 1- |
6 |
Optocoupler emitter for output 1. For sourcing
applications connect "-" to load. For sinking
applications connect "-" to GND.
|
| Output 2+ |
2 |
Optocoupler collector for output 2. For sourcing
applications connect "+" to voltage. For sinking
applications connect "+" to load.
|
| Output 2- |
7 |
Optocoupler emitter for output 2. For sourcing
applications connect "-" to load. For sinking
applications connect "-" to GND.
|
| Output 3+ |
8 |
Optocoupler collector for output 3. For sourcing
applications connect "+" to voltage. For sinking
applications connect "+" to load.
|
| Output 3- |
12 |
Optocoupler emitter for output 3. For sourcing
applications connect "-" to load. For sinking
applications connect "-" to GND.
|
| Input 1 |
5 |
Internal 4.7K pullup resistor to 5V
|
| Input 2 |
11 |
Internal 4.7K pullup resistor to 5V
|
| Input 3 |
13 |
Internal 4.7K pullup resistor to 5V
|
| Analog Input |
15 |
Application program resource
|
| User 5V |
3 |
Available as voltage reference for
analog input. Current limited to 500 ma
|
| GND |
14 |
Same as power supply return
|
| Disable |
9 |
Drive is normally enabled. Apply voltage to disable drive.
|
| RS485+ |
4 |
RS485 Half Duplex signal, sometimes referred to as "A".
|
| RS485- |
10 |
RS485 Half Duplex signal, sometimes referred to as "B".
|