Motion Block
Description
This command
is used to establish the slew speed to be used during axis movement. The parameter is in units of
User Units per second. The speed of a move may be changed on the fly at any point in a move and takes immediate effect if
the motion is in the slew phase. Setting the speed to zero is a way to pause motion activity. The speed value can later be restored
to the previous value and motion will resume.
Escapes
If the speed parameter resolves to a higher step frequency than 2Mhz then a Parameter Out Of Range Escape Code will occur.
Examples
Related Topics
Accel
Decel
Speed
Set Accel