Current Percentage

Text Language Definition

procedure T1Axis.CurrentPercentage;

Description

The Current Percentage commands indicates the active value of current for the motor at the present moment. The value returned is in the range of 0 to 100%. If Variable Current Mode is not active then Current Percentage should indicate the Run Current Percentage while moving and the Reduction Current Percentage when motion has stopped and the reduction delay has occurred. If Variable Current Mode and tracking is active, the Current Percentage will vary depending on load and motor activity.

Escapes

The Current Percentage commands does not produce any escapes.

Examples



Related Topics

Set Max Current
Set Reduction Current To Percentage
Set Run Current To Percentage
Set Variable Current Mode