Modbus Motion Interface
Write_Single(<AxisGroupPage>_+_Decel_s,<Value>);
Read_Single(<AxisGroupPage>_+_Decel_s);
Description
This command
is used to set the deceleration of a profiled move in user units per second squared.
If the Axis Object indicated is a single axis
(T1Axis) the deceleration is for the movement of that motor when operating alone. If the Axis Object represents a multiple axis
group such as a two dimensional (T2Axis) or four
dimensional group (T4Axis), the deceleration applies to the
coordinated motion profile of the group.
Accel
else
Set Accel
may be used to
independently set the Acceleration of the axis or group.
Escapes
If the Decel setting is 0 or negative an User Decells 0 Or Negative Escape Code will occur.
If a new decel value that is issued during a move cannot be achieved with the current direction and speed a Motion Overrun Escape Code will occur.
Examples
Write_Single(Axis1_+_Accel_s, 10);
Write_Single(Axis1_+_Decel_s, 10);
Write_Single(Axis1_+_Speed_s, 2);
Write_Double(Axis1_+_MoveBy_d, 5);
Related Topics
Decel
Set Speed
Set Accel