Modbus Motion Interface
         Read_Double(<AxisPage>_+_PositiveLimit_d,<Value>);
  
        Description
        
        Positive Limit  reports  the  current  positive  limit  setting  for  a  single  axis.  The  positive  limit
establishes the most positive legal value for a move destination. If a move is requested that would
produce a motor position greater than the positive limit, a Position Limit Escape Code is produced and no motion is
performed.  Note  that  position  limits  are  not  used  when  performing  a  jog.  Jogs  are  by  nature
indefinite  moves.
Software limits are always active but can be effectively disabled by being set with large values. 
When designing homing routines it is usually necessary to widen the software limits until the coordinate system is established to afford freedom to search for the home sensor. Once
the origin of the coordinate system is found the limits can be re-established.
        Escapes
        The Positive Limit block does not generate any escapes.
        
        
        Examples
Limit=Read_Double(Axis1_+_PositiveLimit);
  
        Related Topics
        
        Set Run Current To Percentage
        Set Reduction Current To Percentage
        Position Limit Escape Code