Modbus Motion Interface
Read_Double(<AxisPage>_+_PositiveLimit_d,<Value>);
Description
Positive Limit reports the current positive limit setting for a single axis. The positive limit
establishes the most positive legal value for a move destination. If a move is requested that would
produce a motor position greater than the positive limit, a Position Limit Escape Code is produced and no motion is
performed. Note that position limits are not used when performing a jog. Jogs are by nature
indefinite moves.
Software limits are always active but can be effectively disabled by being set with large values.
When designing homing routines it is usually necessary to widen the software limits until the coordinate system is established to afford freedom to search for the home sensor. Once
the origin of the coordinate system is found the limits can be re-established.
Escapes
The Positive Limit block does not generate any escapes.
Examples
Limit=Read_Double(Axis1_+_PositiveLimit);
Related Topics
Set Run Current To Percentage
Set Reduction Current To Percentage
Position Limit Escape Code