Command
<axis> AMP <value>
Description
This command sets the maximum current level for stepper motor operation
in amps.
The Set Run Current Percentage and Set Reduction Current Percentage
commands refer to this command to establish the 100% value. More current does not necessarily mean more torque. If the magnetics saturate additional current only produces additional heat and can interfere with the task of reducing or reversing
current during higher speed movement. Refer to motor specifications to identify the best operating current for any particular motor. Note how the current is specified for the motor and indicate rms or peak as the last list field parameter.
Escapes
Set Maximum Current will not produce an escapecode. If a current setting is beyond the setting for the drive the current will be set to the maximum.
Examples
This shows the maximum current being set to 1.5 amps: