Schedule Task

Modbus Motion Interface

Write_Word(<SystemPage>_+_UserTask<N>_w,>Period value in range 1 to 7FFFh<);

Description

This command causes a procedure in the controller to periodically execute as an independent activity concurrent along with with other tasks and motion. When the task completes it will start again after the indicated period which is expressed in milliseconds. Note that any yields performed by the task are magnified by the period. Each yield is extended in duration to the period value in milliseconds. If a period of zero is provided the task will be scheduled to run at the controller sample rate restarting as soo as it finishes on the next sample. To avoid having every yield be the period in duration it is often more convenient to begin a task that has an explicit loop with a period delay inside the loop at a specific place. Application procedures to be managed as concurrent tasks should be named UserTask1, UserTask2, etc. The task number is referenced by this command.

The MAC Family supports 64 concurrent tasks in addition to concurrent motion which does not consume task resources

The constant "BeginUserTask" is provided to use as the write parameter for the Modbus word write.

Escapes

If all of the available task slots are filled an attempt to start another task will result in an Unable To Begin Task Escape Code. If the task number is specified that is less than 1 or greater than the MaxUserTasks constant inside the interpreter package a Parameter Out Of Range Escape Code error will occur. MaxUserTasks has a value of 16 but can be adjusted if more tasks need to be invoked from the host. Note that only 14 additional tasks can run at one time as two are used to sustain host communication.

Examples

Write_Word(SYSTEM_+_UserTask1, 20);
Write_Word(SYSTEM_+_UserTask2, 100);
Write_Word(SYSTEM_+_UserTask3, 0);

Related Topics

Yield
Abort User Task
User Task Present