Modbus Motion Interface
Read_Word(<AxisPage>_+_CaptureBit_w);
Description
The Capture Bit returns the current value of the signal chosen to be the capture signal for the indicated axis.
The signal is selected with Set Capture Source. This signal is used to trigger the capture latches for precisely
recording an axis position. This command is provided to observe the state of the capture signal independent of the capture
hardware.
Escapes
The Capture Bit register does not produce any escapes.
Examples
if Read_Word(Axis1_+_CaptureBit_w) <> 0 then...
Related Topics
Arm Capture
Capture Has Tripped
Capture Position
Set Capture Trip
Set Capture Source