Modbus Motion Interface
Write_Word(<AxisOrGroupPage>_+_BeginStop_w,0);
Description
The Set Capture Source register is used to indicate which input will be used for a capture event.
Escapes
The Set Capture Source block does not produce any escapes
Examples
The following sequence of operations configures the capture system, commences a moves, and recovers the capture position
Write_Word(Axis1_+_SetCaptureSource_w.1);
Write_Word(Axis1_+_SetCaptureTrip_w,1);
Write_Word(Axis1_+_ArmCapture_w,1);
Write_Double(Axis1_+_BeginMoveBy_d,25.7);
WaitUntilWordRegisterIsNonZero(Axis1_+_ArmCapture_w);
CapturePosition:=Read_Double(Axis1_+_CapturePosition_d);
Related Topics
Capture Position
Set Capture Trip
Capture Has Tripped
Capture Bit
Arm Capture