Introduction Welcome Methods of Use Communication Matrix Version Information Bug Reporting Controller Description Specifications Communication Ports Controller Power Inputs and Outputs LED Indicators Motion System Connectors Power Connector Signal Connector Menu Reference File New Project Open Project Open Recents Open Resources Save Save As Save In Controller View Pascal Listing Hints Task Monitor Assembly Listing Symbol Tree Configure Communication Port Auto Drop Down Data Drop Down Compile To Flash Conditional Defines Remote Network Run Start App Stop App Help Block Help Text Help About Language Description Formats and Conventions Variables Assignment Constants Operators Procedures and Functions Control Structures If If..Else Loop..Do For..Do While..Do Repeat..Until Try..Recover User Defined types Motion Abort Accel Actual Position Begin Move By Begin Move To Begin Stop Commanded Position Coordinate Inversion Counts Per User Unit Current Percentage Decel Deflection Destination Position Init Jog Motor Is On Move By Move Is Finished Move To Negative Limit Positive Limit Profile Phase Profile Velocity Quiet Mode Rotor Lead Lag Rotor Lead Lag Time Rotor Locked Run Current Set Accel Set Actual Position Set Commanded Position Set Counts Per User Unit Set Decel Set Max Current To Set Motor Set Negative Limit Set Positive Limit Set Quiet Mode Set Reduction Current To Percentage Set Reduction Delay Set Rotor Locked Timeout Set Run Current To Percentage Set Speed Speed Stop Set Tracking Set Tracking Speed Set Variable Current Mode Multitasking Abort Task Begin Task Schedule Task Schedule Last Task Task Present IO Operations Sample Counter Safety Firmware Version Reset Watchdog User Has Disabled Watchdog Has Tripped Motion Concepts User Units Motor States Homing Escape Codes 10 Divide Overflow Escape Code 11 Sample Overrun Escape Code 12 Axis Not Valid Escape Code 13 Speed Negative Escape Code 16 User Accels 0 Or Negative Escape Code 17 User Decells 0 Or Negative Escape Code 19 Unable To Resume Task Escape Code 20 Unable To Begin Task Escape Code 23 Motion Overrun Escape Code 24 Axis Is Busy Escape Code 25 File Reset Escape Code 26 File Rewrite Escape Code 27 Read Escape Code 28 Write Escape Code 29 Object Not Initialized Escape Code 31 Parameter Out Of Range Escape Code 32 Watchdog Failed To Reset Escape Code 33 Option Not Present Escape Code 34 IO Authorization Escape Code 35 Name Not Found Escape Code 36 Library Not Found Escape Code 37 DLL Procedure Not Found Escape Code 39 String Error Escape Code 40 Floating Point Error Escape Code 41 Task Stack Overflow Escape Code 42 Address Is Nil Escape Code 44 Plate Not Present 45 Position Limit Escape Code 47 Task Address Is Not Valid Escape Code 48 Bitmap File Not Found Escape Code 49 Capture Not Present Escape Code 50 Encoder Position Not Present Escape Code 51 Dac Number Out Of Range Escape Code 52 Function Not Present Escape Code 53 Axis Does Not Support Enable Status Escape Code 54 Firmware Read Escape Code 55 Ethernet Socket Initialization Failed Escape Code 56 Ethernet Socket Initialized With Port 0 Escape Code 57 Ethernet Socket Already In Use Escape Code 58 Ethernet Socket Limit Exceeded Escape Code 59 Modbus Communication Package Required Escape Code 60 Watchdog Has Tripped Escape Code 61 Unresponsive Remote Controller Escape Code Deployment Commissioning Updating Firmware